Sterilight S5Q-PA Specifications | ||||||
---|---|---|---|---|---|---|
Applications | point-of-use cabin |
|||||
Max. Flow Rate (UV dose >30 mJ/cm2)* |
6 GPM (23 LPG) | |||||
Max. Flow Rate (UV dose >40 mJ/cm2)* |
4.5 GPM (17 LPM) | |||||
Water Chamber Material | 304 Stainless Steel | |||||
Chamber Length | 21.0 inches / 53.3 cm | |||||
Chamber Diameter | 2.5 inches / 6.4 cm | |||||
Controller Size | 7.3 x 3.2 x 2.5 inches (19.0 x 8.1 x 6.4 cm) |
|||||
Lamp | Sterilume-EX Model S463RL |
|||||
Sleeve | Quartz Model QS-463 |
|||||
Electrical | 100-240v, 50/60HZ | |||||
Power Consumption | 30 watts | |||||
Lamp Power | 24 watts | |||||
Inlet / Outlet Plumbing Ports | 3/4" MNPT | |||||
"Power-On" Indicator Light | ||||||
Audible Lamp Failure Alarm | ||||||
Lamp Replacement Reminder | ||||||
LED Display: Lamp Life Remaining, Total Controller Runtime | ||||||
Warranty | Reaction Chamber: 7 years Lamp: 1 year All Other components:2 years |
*Note: Maximum recommended flow rates based on 95% UV transmittance. Actual dosage depends on flow rate, water quality, and maintenance (cleaning ov UV sleeve). UV dosage will be lower when the UV transmittance capacity of the water drops below 95% - if in doubt, select a model rated for a higher flow rate than you actually require. We recommend a UV dose of 40 mJ/cm2.
Feed Water Quality Parameters | |
---|---|
Iron | 0.3 ppm (0.3 mg/L) |
Manganese | 0.05 ppm (0.05 mg/L) |
Tannins | 0.1 ppm (0.1 mg/L) |
Turbidity | < 1 NTU |
Hardness | < 120 ppm (7 grains / gallon) |
UV Transmittance (UVT): | 75% |
Maximum Temperature: | 104F (40C) |
Maximum Pressure: | 125 psi |